201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
according to the number of doors. Before using the device (including doors), the user must edit door information one by one
(or apply current settings to other doors). After editing, they will be sent to the device, which can be used after successful
setting.
(1) Door Parameter Modification:
Select the door to be modified, and click [Edit] under “Related Operation” to show the edit interface;
The fields are as follows:
Device Name: It is not editable (must be edited in 5.2.1 Add Access Control Panel);
Door Number: The system automatically names the numbers of doors according to how many doors the device has (for
example, the four doors of a four-door control panel are numbered 1, 2, 3 and 4). The number will be consistent with the door
number on the device.
Note: By default the number following the underline in the door name is consistent with the door number, but 1/2/3/4 in
anti-pass back and interlock refers to the door serial number rather than the number following the door name. They are not
necessarily related. The system allows the user to modify the door name so that they are not confused;
Door Name: The default Door Name is “device name_door number”. The field allows the user to modify as required. Up to 30
characters can be entered;
Door Active Time Zone,
Passage Mode Time Zone: By default both are null. Initialized and added access control time
zones will be shown for the user to select. Upon door editing, the door valid time zone is needs to be input. Only after setting
the door valid time zone, the door can be opened and closed normally. We recommend to set the door Normal Open time
period within the door valid time zone, only in this situation, the door Normal Open time zone is valid;
Note: Consecutive punching of a card having access level of the door 5 times can release the Normal Open status for
one day (including First-Card Normal Open), and close the door immediately.
Lock Drive Duration: Used to control the delay for unlocking after card punching. The unit is seconds, and the default is 5
seconds. The user can enter a number between 0-254;
Punch Interval: The unit is seconds (range: 0-10 seconds), and the default is 2 seconds;
Door Sensor Type: NO (door sensor not detected), Normal Open, Normal Close. The default is NO. When editing doors, the
user can select the door sensor type to be Normal Open or Normal Close. If Normal Open or Normal Close is selected, it is
required to select door status delay and whether close and reverse-lock is required. By default, once door sensor type is
set as Normal Open or Normal Close, the default door status delay will be 15 seconds, and by default it will enable Close and
Reverse-lock.
Door Status Delay: The duration for delayed detection of the door sensor after the door is opened. Detection is performed
only after the door is opened and the delay duration expired. When the door is not in the “Normal Open” period and the door is
opened, the device will start timing. It will trigger an alarm when the delay duration expired, and stop the alarm when you close
the door. The default door status delay will be 15 seconds. The door status delay should be longer than Lock Drive
Duration.